Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Pull-off Force of Four Different Implant Cements Between Zirconia Crowns and Titanium Implant Abutments in Two Different Abutment Heights
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 42 , Issue 3
May/June 2022

Pages e67–e74


Pull-off Force of Four Different Implant Cements Between Zirconia Crowns and Titanium Implant Abutments in Two Different Abutment Heights


Hanna Volkmann, DMD/Angelika Rauch, Priv-Doz Dr Med Dent/Andreas Koenig, Priv-Doz Dr Rer Nat/Oliver Schierz, Priv-Doz Dr Med Dent


PMID: 35472113
DOI: 10.11607/prd.4926

This study evaluated the pull-off force between titanium abutments and zirconia crowns that were bonded using four different cements and two abutment heights (AHs). In total, 24 titanium abutments (3-mm AH: n = 12; 5-mm AH: n = 12; taper: 7.5 degrees) and 24 zirconia crowns were designed, manufactured, cemented with one of four dental cements (one temporary, two semi-permanent, one permanent), stored in water for 24 hours, and thermocycled (37,500 cycles, equal to ~4 years in vivo). The pull-off force needed to separate the abutment and crown in each combination was determined eight times per combination of cement type and abutment height. Statistical analysis was conducted at a significance level of P < .05. The permanent self-adhesive composite cement showed a high pull-off force with a risk for crown fracture (mean: 381 N for 3-mm AH; 617 N for 5-mm AH). In contrast, the temporary zinc-oxide cement showed frequent premature decementation after thermocycling (mean: 14 N with 3-mm AH; 28 N with 5-mm AH). Both semi-permanent methacrylate-based cements ranked between the other cements (mean: 31 N/37 N for 3-mm AH; 120 N/72 N for 5-mm AH). Statistically significant differences were found between all cements (ANOVA P < .001). The abutment heights differed significantly for all cements (P < .005) except for the temporary zinc-oxide cement. Methacrylate-based cements were the most reliable cements for semi-permanent mounting of zirconia crowns on titanium abutments. They provide sufficient retention to avoid unintended loosening and are weak enough to remove the crown without causing damage.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help